| LIQUID HANDLING - Microplate
Dispensers |
|
| Company Name |
Product Name |
Image |
Microplate
Formats |
Plate Capacity |
Number of channels |
Dead Volume |
Dispense Volume |
Dispensing Precision |
Integratable |
|
| 96 |
384 |
1536 |
|
| Beckman
Coulter, Inc. |
BioRAPTR FDR™ |
|
Yes |
Yes |
Yes |
1 |
4,8,16 |
70 uL - 1.5 mL |
100nL - 60 uL |
15% @ 800nL |
Top loading and
Articulated Robots |
|
| Bio-Tek®
Instruments, Inc |
µFill™ |
|
Yes |
Yes |
No |
1 |
8,16 |
20
mL/non autoclavable pump
10 mL/autoclavable pump |
96
10uL - 3000uL 384 5uL- 1500uL |
1%
@ 100uL |
Top
loading and Articulated Robots |
|
| Bio-Tek® Instruments, Inc |
Precision™ |
|
Yes |
Yes |
No |
6 |
8 |
20
mL/non autoclavable pump
10 mL/autoclavable pump |
10uL
- 10mL |
1%
@ 100uL |
Top
loading and Articulated Robots |
|
| Bio-Tek® Instruments, Inc |
Precision™ XS |
|
Yes |
Yes |
No |
6 |
8 |
20
mL/non autoclavable pump
10 mL/autoclavable pump |
10uL
- 10mL |
1%
@ 100uL |
Top
loading and Articulated Robots |
|
| Brandel |
PXR-96-MS |
|
Yes |
Yes |
No |
1 |
8 |
N/A |
10
µL-9999 µL |
<3% @ 100 µL |
Top
loading and Articulated Robots |
|
| Deerac Fluidics™ |
Equator™
HTS |
|
Yes |
Yes |
Yes |
1 |
8 |
10
µL/ Channel
3 µL minimum aspriate volume |
0.05
µL- 50 µL |
Above
1µL <5%
At 0.5 µL <7%
At .05 uL <10% |
|
|
| Genetix |
Qfill
2 |
|
Yes |
Yes |
No |
1 |
8,16 |
N/A |
20
µL-2 mL |
<5% @ 20 µL |
Top
loading and Articulated Robots |
|
| Innovadyne Technologies, Inc. |
Nanodrop™
I |
|
Yes |
Yes |
Yes |
1 |
8 |
1.44uL/Channel |
.1
-40 uL (Non-Contact)
25 - 500 (Contact) |
<1%
@ 5uL |
Top
loading and Articulated Robots |
|
| Innovadyne Technologies, Inc. |
Nanodrop™
II |
|
Yes |
Yes |
Yes |
2 |
8 |
1.44uL/Channel |
.1
-40 uL (Non-Contact)
25 - 500 (Contact) |
<1%
@ 5uL |
Top
loading and Articulated Robots |
|
| Innovadyne Technologies, Inc. |
Screenmaker96+8™ |
|
Yes |
Yes |
Yes |
4 |
96/8 |
<1uL/Channel |
.1
-40 uL (Non-Contact)
25 - 500 (Contact) |
<1%
@ 5uL |
Top
loading and Articulated Robots |
|
| Labcyte |
MiniGene
Line Dispenser |
|
Yes |
Yes |
Yes |
1 |
8 |
N/A |
5ul
- 2ml |
5%
@ 5ul |
Top
loading and Articulated Robots |
|
| Perkin Elmer Life and Analytical Science |
FlexDrop™
III |
|
Yes |
Yes |
Yes |
1 |
8 |
N/A |
200nL
- 2mL |
5%
@ 500nL |
Top
loading and Articulated Robots |
|
| Thermo Electron
Corporation |
Multidrop™
384 |
|
Yes |
Yes |
No |
1 |
8 |
N/A |
5
µL-100 µL |
<1.5% @ 20µL |
Top
loading and Articulated Robots |
|
| Thermo Electron
Corporation |
Multidrop™ 96 |
|
Yes |
No |
No |
1 |
8 |
N/A |
5
µL-395µL |
<1.5% @ 20 µL |
Top
loading and Articulated Robots |
|
| Thermo Electron
Corporation |
Multidrop™
Deep Well |
|
Yes |
No |
No |
1 |
8 |
N/A |
20
µL-955 µL |
<1.5% @ 20 µL |
Top
loading and Articulated Robots |
|
| LIQUID HANDLING - Volume Verification Systems |
|
| Company Name |
Product Name |
Image |
Microplate Formats |
Liquid contact/Non Contact System |
Volume Range 96 and 384 |
Inaccuracy |
Imprecision |
|
| 24 |
48 |
96 |
384 |
1536 |
| Artel |
Artel
MVS (Multichannel Verification System) |
|
No |
No |
Yes |
Yes |
No |
Liquid |
0.100-200μl(96) 0.0100-55μl(384) |
Less than 3% |
Less than 1.5%
CV |
|
| BioMicroLab, Inc |
VolumeCheck |
|
Yes |
Yes |
Yes |
No |
No |
Non Contact |
No set range |
Volume
changes according to what plate is being tested |
Volume changes
according to what plate is being tested |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|